Power Cable Fault Locator for Rough Measurement and Accurate Fault Detection

Power Cable Fault Locator for Rough Measurement and Accurate Fault Detection

Λεπτομέρειες προιόντος:
Τόπος καταγωγής: Xi'an ShanXi Κίνα
Μάρκα: XZH TEST
Πιστοποίηση: ISO/CE
Αριθμό μοντέλου: XHHG521B
Πληροφορίες λεπτομέρειας
Τόπος καταγωγής:
Xi'an ShanXi Κίνα
Μάρκα:
XZH TEST
Πιστοποίηση:
ISO/CE
Αριθμό μοντέλου:
XHHG521B
Επισημαίνω:

High Light

Επισημαίνω:

Rough Measurement Power Cable Fault Locator

,

Power Cable Fault Locator

,

Fault Locator for Rough Measurement

Trading Information
Ποσότητα παραγγελίας min:
1 σετ
Συσκευασία λεπτομέρειες:
Ξύλινη συσκευασία
Χρόνος παράδοσης:
5-8 εργάσιμες
Όροι πληρωμής:
T/T
Δυνατότητα προσφοράς:
3000 μονάδες/έτος
Περιγραφή προϊόντων
XHHG521B
The Power Cable Fault Locator provides efficient rough measurement capabilities for identifying faults in power cable systems.

The device uses an electric voltage regulator and an R-type transformer to form a high-voltage constant-current source, with push-button operation for voltage increase and decrease. It has a no-load voltage of 5600V and a short-circuit current of 100mA. It uses a high-sensitivity amplifier and a galvanometer to indicate balance, forming a balanced bridge with a proportional potentiometer, all at high potential. The measurement cable is a specially designed two-core high-voltage rubber cable, and a four-terminal resistance measurement method is used to eliminate errors introduced by lead resistance. The panel is maintained at low potential.

Key Features
  • Accurate rough measurement of cable faults
  • Designed for power cable systems
  • Efficient fault location capabilities


The cable sheath fault tester is particularly suitable for:

1. High-resistance breakdown points in cables after installation, especially linear high-resistance breakdown points that are difficult to burn down to low resistance, such as those at intermediate cable joints.

2. Flashover breakdown points, where the constant current source can maintain the arc after breakdown, a stable current flows through the bridge, and the bridge has sufficient sensitivity.

3. Low-resistance defects that have not yet broken down, such as insulation defects detected by a megohmmeter at low cable resistance but not breaking down under the operating voltage.